Application:
Intended for numerous commercial or residential applications,
including basement flooding, sump pits, laundry water,
and flooding in low-lying areas.
Features:
Discharge Size................................1-1/4" MNPT
Power Supply...................................115V, 60 HZ
Motor Duty.........................................Intermittent
Motor Type........................................PSC Motor
Min. Amps for Dedicated Circuit...................15 Amps
Temperature of Liquids Pumped.................32F to 104F
Discharge Adapter Sizes...............................1-1/4"FNPT Elbow
............................................................1-1/4"MNPT--1-1/2"FNPT Adapter
Speed................................................3450RPM
Max Size of Solid.............................3/4"
Pump Housing................................Stainless Steel
Base&Top........................................Stainless Steel
Motor Housing.................................Stainless Steel
Impeller.............................................Stainless Steel
Shaft&Hardware..............................Stainless Steel
Performance Chart:
HP |
Max Amps |
GPM @Total Feed of Head |
MAX Head |
5ft |
10ft |
15ft |
20ft |
3/4 |
6.4 |
45.5 |
34.0 |
21.5 |
12.0 |
26.2 |